2015-10-07 Product news
Low speed ventilation delivers highly efficient server cooling
Low Speed Ventilation (LSV) – a new, highly efficient cooling concept for server rooms – is the latest addition to Alfa Laval’s range of cooling solutions for data centers.
Millions of servers in data centers worldwide generate huge amounts of heat while handling and processing data. Conventional server cooling technology involves high air speeds of 8-9 metres per second. Moving air at this speed requires a lot of energy and can trigger the Venturi-effect, which leads to air pressure variations and the “hot spots” that can cause servers to overheat.
Alfa Laval has introduced a unique and patented cooling concept, Low Speed Ventilation, which delivers air at a considerably lower speed: 1.5 to 1.8 meters per second. Reducing air speed and delivering an optimum airflow eliminates the Venturi effect, minimizes pressure differences and therefore prevents problems such as ‘hot spots’. As LSV is a normal pressure technology, data center operators only need to control air availability, not air pressure, making it far easier to achieve optimum conditions in the server room.
As significant amounts of air are required for Low Speed Ventilation, LSV coolers are larger than conventional coolers. Alfa Laval Arctigo LSV air coolers are specially designed with a large cross-sectional area. Located outside the server room, these coolers ensure the servers are supplied with sufficient temperature-controlled air at all times, while consuming far less power than conventional server cooling solutions.
“Low Speed Ventilation is a unique technology that challenges current solutions for cooling server halls,” says Mats Carselid, Marketing Manager Data Center Cooling. “We live in an age obsessed with speed, so it may feel counter-intuitive that you can improve performance by slowing something down. However, our new concept shows that if you reduce air velocity, you can avoid problems often encountered in conventional server cooling and gain a lot of benefits such as increased energy efficiency and reduced energy costs. Just the fact that Low Speed Ventilation technology allows server halls to operate under normal air pressure makes it a true innovation.”
LSV technology, which is already operating successfully at server halls in the Netherlands, is now available in the Nordic countries.
LSV: key benefits
- Lowest PUE – Power Usage Effectiveness of 1.07 compared to market average for global data centers of 1.5.
- Lower energy consumption – “leaner cooling”, as EC fans distribute air to servers at low speed.
- Easier maintenance – LSV coolers are located outside the server room, making service access more convenient.
- Lower costs – reduces cooling-related energy bills by up to 30% depending on size, type and location of the data center
LSV coolers for server halls join the existing range of Alfa Laval products such as gasketed plate heat exchangers, dry coolers and adiabatic coolers, which can be combined in integrated systems to meet a data center’s overall cooling needs.
For further information contact:
Mats Carselid, Marketing Manager Data Center Cooling,
Alfa Laval Lund AB, Lund, Sweden
+46 46-36 65 30
mats.carselid@alfalaval.com
Klaudija Cavala, Central Market Communication Manager, Industrial Equipment Segment
Alfa Laval Lund AB, Lund, Sweden
+46 46 36 77 57
klaudija.cavala@alfalaval.com
See more at: http://www.alfalaval.com/datacenter